Parker Autoclave: Series ASL10-01

Series ASL10-01

High Flow, Low Pressure Single Piston Air-Driven Fill Pump

 

• Actual Air to Liquid Pressure Ratio = 1:11

• Flow Rate @ 1 psi = 5 GPM (19 LPM)

• Maximum Outlet Pressure = 1,600 psi (110 bar)

 

| Read more Product Information |

   
 

Series ASL25-01

High Flow, High Pressure, Double Acting, Dual Piston Air Driven Liquid Pump

 

• Actual Air to Liquid Pressure Ratio = 1:28

• Flow Rate @ 1 psi = 2.3 GPM (8.7 LPM)

• Maximum Outlet Pressure = 4,100 psi (283 bar)

 

| Read more Product Information |

 

   
 

Series ASL35-01

High Flow, High Pressure, Double Acting, Dual Piston Air Driven Liquid Pump

 

• Actual Air to Liquid Pressure Ratio = 1:39

• Flow Rate @ 1 psi = 1.4 GPM (5.3 LPM)

• Maximum Outlet Pressure = 5,600 psi (386 bar)

 

| Read more Product Information |

 

   

   
   
Parker Autoclave: Series ASL10-02

Series ASL35-02

Single Acting , Dual Piston Air-Driven Hydraulic Pump

 

• Actual Air to Liquid Pressure Ratio = 1:78

• Volume Displacement per Stroke = 1.50 in³ (24.6 cm³)

• Maximum Outlet Pressure = 11,200 psi (772 bar)

 

| Read more Product Information |

 

   
   

   
Parker Autoclave: Series ASL60-01

Series ASL60-01

Single Acting, Low Pressure Single Piston Air-Driven Hydraulic Pump

 

• Actual Air to Liquid Pressure Ratio = 1:70

• Volume Displacement per Stroke = 0.84 in³ (13.7 cm³)

• Maximum Outlet Pressure = 10,000 psi (690 bar)

 

| Read more Product Information |

 

Parker Autoclave: Series ASL60-01

Series ASL60-02

Single Acting , Dual Piston Air-Driven Hydraulic Pump

 

• Actual Air to Liquid Pressure Ratio = 1:144

• Volume Displacement per Stroke = 0.84 in³ (13.8 cm³)

• Maximum Outlet Pressure = 20,000 psi (1,379 bar)

 

| Read more Product Information |

   

   
Parker Autoclave: Series ASL100-01

Series ASL100-01

Single Acting, High Pressure, Single Piston Air-Driven Liquid Pump

• Actual Air to Liquid Pressure Ratio = 1:113

• Volume Displacement per Stroke = 0.52 in³ (8.5 cm³)

• Maximum Outlet Pressure = 15,000 psi (1034 bar)

 

| Read more Product Information |

 

   
Parker Autoclave: Series ASL100-02

Series ASL100-02

Single Acting, High Pressure, Double Piston Air-Driven Liquid Pump


• Actual Air to Liquid Pressure Ratio = 1:226

• Volume Displacement per Stroke = 0.52 in³ (8.5 cm³)

• Maximum Outlet Pressure = 31,000 psi (2137 bar)

 

| Read more Product Information |

   

   
Parker Autoclave: Series ASL150-01

Series ASL150-01

Single Acting, High Pressure, Single Piston Air-Driven Liquid Pump

• Actual Air to Liquid Pressure Ratio = 1:150

• Volume Displacement per Stroke = 0.39 in³ (6.4 cm³)

• Maximum Outlet Pressure = 21,500 psi (1482 bar)

 

| Read more Product Information |

 

   
Parker Autoclave: Series ASL150-02

Series ASL150-02

Single Acting, High Pressure, Double Piston Air-Driven Liquid Pump

• Actual Air to Liquid Pressure Ratio = 1:300

• Volume Displacement per Stroke = 0.39 in³ (6.4 cm³)

• Maximum Outlet Pressure = 43,000 psi (2965 bar)

 

| Read more Product Information |

   

   
Parker Autoclave: Series ASL250-01

Series ASL250-01

Single Acting, High Pressure, Single Piston Air-Driven Liquid Pump

• Actual Air to Liquid Pressure Ratio = 1:265

• Volume Displacement per Stroke = 0.22 in³ (3.6 cm³)

• Maximum Outlet Pressure = 38,400 psi (2648 bar)

 

| Read more Product Information |

 

   
   

   
Parker Autoclave: Series ASL400-01

Series ASL400-01

Single Acting, High Pressure, Single Piston Air-Driven Liquid Pump

• Actual Air to Liquid Pressure Ratio = 1:398

• Volume Displacement per Stroke = 0.14 in³ (2.3 cm³)

• Maximum Outlet Pressure = 57,700 psi (3978 bar) 

 

| Read more Product Information |

   
Parker Autoclave: Series ASL400-02

Series ASL400-02

Single Acting, High Pressure, Double Piston Air-Driven Liquid Pump

• Actual Air to Liquid Pressure Ratio = 1:796

• Volume Displacement per Stroke = 0.14 in³ (2.3 cm³)

• Maximum Outlet Pressure = 60,000 psi (4137 bar) 

 

| Read more Product Information |